Process measurement and control implies continuously changing variable data and/or control methods in an industrial process. Different from discrete (ON/OFF) states, numeric values over a set range are sensed or transmitted in continuous (flow production) or batch (a set quantity or output) processing. Pressure, flow, level and temperature are common process variables.
ProSense liquid flow sensor, vortex, 3/4in female NPT process connection, 1.3 to 26.4 GPM, 80 to 1585 GPH, 14 to 194 deg F, Output: switch or frequency, Output 2: switch or frequency, 18 to 30 VDC operating voltage. Learn More
ProSense liquid flow sensor, vortex, 1/2in female NPT process connection, 0.55 to 10.55 GPM, 32 to 634 GPH, 14 to 194 deg F, Output: switch or frequency, Output 2: switch or frequency, 18 to 30 VDC operating voltage. Learn More
ProSense liquid flow sensor, vortex, 1/2in female NPT process connection, 0.26 to 5.28 GPM, 16 to 317 GPH, 14 to 194 deg F, Output: switch or frequency, Output 2: switch or frequency, 18 to 30 VDC operating voltage. Learn More
ProSense liquid or air flow sensor, thermal, 200mm probe length, liquid: 0.15 to 9.85 ft/sec, air: 6 to 328 ft/sec, -4 to 212 F, Output: switch or frequency, Output 2: switch, frequency or analog, 18 to 30 VDC operating voltage. Learn More
ProSense liquid or air flow sensor, thermal, 100mm probe length, liquid: 0.15 to 9.85 ft/sec, air: 6 to 328 ft/sec, -4 to 212 F, Output: switch or frequency, Output 2: switch, frequency or analog, 18 to 30 VDC operating voltage. Learn More
ProSense liquid flow meter, magnetic-inductive, 2 inch female NPT process connection, 0 to 160 GPM, -4 to 176 F, 0.02 to 20,000 GPP, Output: switch, pulse or frequency, Output 2: switch, analog or reset input, 18 to 32 VDC operating voltage. Learn More
ProSense liquid flow meter, magnetic-inductive, 1-1/2 inch female NPT process connection, 0 to 80 GPM, -4 to 176 F, 0.02 to 20,000 GPP, Output: switch, pulse or frequency, Output 2: switch, analog or reset input, 18 to 32 VDC operating voltage. Learn More
ProSense liquid flow meter, magnetic-inductive, 1 inch female NPT process connection, 0 to 26.4 GPM, -4 to 176 F, 0.01 to 10,000 GPP, Output: switch, pulse or frequency, Output 2: switch, analog or reset input, 19 to 30 VDC operating voltage. Learn More
ProSense liquid flow meter, magnetic-inductive, 3/4 inch female NPT process connection, 0 to 13.2 GPM, -4 to 176 F, 0.01 to 10,000 GPP, Output: switch or pulse, Output 2: switch, analog or reset input, 19 to 30 VDC operating voltage. Learn More
ProSense liquid flow meter, magnetic-inductive, 1/2 inch female NPT process connection, 0 to 6.6 GPM, -4 to 176 F, 0.01 to 10,000 GPP, Output: switch or pulse, Output 2: switch, analog or reset input, 19 to 30 VDC operating voltage. Learn More