 | Processors Four processor solutions are available, which differ primarily in user memory size, speed of execution, and numbers of analogue loops/alarms. All models include built-in Ethernet, USB, and serial communications, as well as support for a removeable SD flash card. C200, C300, and C400 models also include built-in Profibus-DP and RS485 Remote I/O. |
| |
 | I/O Adapters Series 500 Adapters allow the use of CTI 2500 Series products in Texas Instruments Series 500 I/O bases. They provide a transparent path for upgrading old Series 500 systems without the requirement to completely replace the system. Failed 500 Series I/O modules can be replaced with CTI 2500 Series modules. Then, when your budget allows, you can plan a complete replacement of your system to CTI 2500 Series - without losing your investment in the replaced modules!
- 2500-IADP - I/O Adapter for Series 500
- 2500-PADP - Power Supply Adapter for Series 500
- 2500-RADP - RBC Adapter for Series 500
|
| |
 | Rack Power Supplies Four power supply solutions are available which differ in their input voltage and load capacity. Our AC supplies feature automatic voltage switching and provide up to 100W of power to the base. They also feature a much longer hold-up time than available in the Siemens® power supply.
- 2512 - 115/230 vAC powered - 75 watt (505-6660 is only 55 watt)
- 2513 - 24 vDC powered - 75 watt
- 2515 - 115/230 vAC powered - 100 watt (for power hungry I/O in large bases)
- 2510 - 125 vDC powered (for DC standby systems)
|
| |
 | I/O Bases Three different mounting base options provide flexibility for many local and remote configurations.
- 2500-R4 - Four slot base
- 2500-R8 - Eight slot base
- 2500-R16 - 16 slot base
|
| |
 | Remote Base Controllers Remote Base Controllers allow the connection of additional I/O bases to the CPU. Both Profibus-DP and RS485 Remote I/O RBCs are available to support all your existing installations, regardless of the connection technology used, and as an upgrade path from RF based RBC systems.
- 2500-RBC - Profibus Remote Base Controller
- 2500-RIO - RS485 Remote Base Controller
|
| |
 | Digital I/O modules Digital I/O modules are available in densities of 8, 16, and 32 points. A full range of input and output voltages from 12 vDC to 240 vAC, and output currents up to 2A per channel are supported. Universal selectable 8/16/32 point modules are available that replace a wide range of legacy 505 Series, and are an ideal choice as spares for both 505 and 500 series I/O systems. |
| |
 | Analogue I/O modules A full selection of analogue I/O is available, with densities of 8 to 16 points per module, analogue in, analogue out, mixed analogue, isolated and non-isolated. Our 2501, 2558, and 2562 modules are direct wiring-compatible replacements for Siemens® 505-7012/7016, 505-6108, and 505-6208 modules.
- 2501 - 8in/4out Analogue Module
- 2550-A - 8-Channel Isolated Analogue Input Module
- 2555-A - 16-Channel Analogue Input Module
- 2558 - 8-Channel Analogue Input Module
- 2560-A - 8-Channel Isolated Analogue Output Module
- 2562 - 8-Channel Analogue Output Module
|
| |
 | Temperature Input A complete suite of temperature measurement solutions is available which covers all common thermocouple and RTD types, with densities up to 16 channels per module, isolated and non-isolated.
- 2551-A - 8-Channel Isolated Thermocouple Input Module
- 2556 - 16-Channel Isolated Thermocouple Input Module
- 2559-TC - 8-Channel Thermocouple Input Module
- 2552-A - 8-Channel Isolated RTD Input Module
- 2557 - 16-Channel RTD Input Module
- 2559-RTD - 8-Channel RTD Input Module
|
| |
 | Relay Output modules CTI relay output modules feature output current up to 6A per point and individually fused outputs.
- 2530 - 8-Point Form-C Relay Output Module
- 2531 - 32-Point Form-A Relay Output Module
- 2532 - 16-Point Form-A Relay Output Module
- 2534 - 8-Point Form-C Relay Output Module
|
| |
 | Communications Communication adapters are available to allow connection of Ethernet, Profibus, Modbus, Serial, and DeviceNet devices. Three different Ethernet solutions give you flexibility to connect to any available Ethernet media.
- 2572 - Ethernet TCP/IP Adapter
- 2572-A - Fast Ethernet TCP/IP Adapter
- 2572-AF - Fast Ethernet TCP/IP Adapter with Optical Fiber Connection
- 2577 - Profibus DP Slave Adapter
- 2573-MOD/TMC2 - Serial Interface Adapter with MODBUS
- 2576 - DeviceNet™ Scanner Module
- 2541 - Redundant Processor Manager Module
|
| |
 | Special modules Specialized I/O modules are available for high speed counting and vibration monitoring applications.
- 2505 - Vibration Sensor Interface Module
- 2553-A - 2-Channel Magnetic Flow Meter Input Module
- 2554-A - 4-Channel Isolated High Speed Counter Module
|
| |
 | Software CTI connectivity software solutions allow you to connect MMI / HMI and programming devices to the 2500 Series or Simatic® 505 system over Ethernet.
- OPC-SM505 - Ethernet / Serial Simatic 505 OPC/DDE Server Suite, with FREE HMI software
- 2572-OPC - Ethernet OPC Server Suite
- 2572-DDS2 - Ethernet DDE Server
- 3102 - APTnet. Communicate with any Simatic® 505 system in your plant using Ethernet and the CTI 2572-A
|
| |